Wood calculators / Bounded elastic models
Measure the wood. State the basis.
Wood Column Euler Model Calculator
Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E.
Your wood & project inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Euler critical load = π² E Iweak / (K L)²; Iweak is the smaller rectangular principal second moment.
Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E.
- Confirm the physical, product or tally basis and use the stated units.
- Enter actual measurements and justified properties, prices or project allowances.
- Submit the form, then interpret the result with the assumptions and limits below.
Not an allowable wood-column, post or stud capacity. Crushing, imperfections, eccentricity, end restraint verification, NDS column factors, connections and load combinations are excluded.
Wood Column Euler Model: formula, units and interpretation
Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E. Not an allowable wood-column, post or stud capacity. Crushing, imperfections, eccentricity, end restraint verification, NDS column factors, connections and load combinations are excluded.
Separate the measured physical quantity from the purchase or design convention. Nominal lumber names, finished dimensions, geometric board feet, log-rule yield, stacked cords and mass describe different things. The method on this page uses only the basis stated beside its inputs; do not replace a missing property with an unrelated unit or trade name.
Before using the answer for a real project, confirm measurements and the relevant supplier information. Entered waste, prices, material properties and limits remain user choices. A rounded purchasing count is a quantity allowance rather than a cutting plan, and a calculated physical response is not a building-code approval.
Continue with: Wood Beam Elastic Deflection Calculator · Wood Beam Model Load Bound Calculator · Wood Beam Elastic Span Bound Calculator · Wood Beam Model Depth Bound Calculator
Check the numbers
Wood Column Euler Model Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not stock recommendations, current quotes, code design values or full standards tables.
Worked example with stated inputs
Dimension units = Metric (m / mm); Rectangular first side = 100 mm; Rectangular second side = 150 mm; Unbraced ideal member length = 3 m; User-supplied E = 10000 MPa; Ideal effective length factor = 1 ratio.
| Output | Computed result |
|---|---|
| Ideal elastic Euler critical load | 137.077839 kN critical |
| Weak-axis second moment | 1.25e-5 m⁴ |
| Effective length | 3 m |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 1.5 m | Unbraced ideal member length | 548.311356 kN critical |
| 2.25 m | Unbraced ideal member length | 243.693936 kN critical |
| 3 m | Unbraced ideal member length | 137.077839 kN critical |
| 3.75 m | Unbraced ideal member length | 87.729817 kN critical |
| 4.5 m | Unbraced ideal member length | 60.923484 kN critical |
| 6 m | Unbraced ideal member length | 34.26946 kN critical |
Unchanged inputs use: Dimension units = Metric (m / mm); Rectangular first side = 100 mm; Rectangular second side = 150 mm; Unbraced ideal member length = 3 m; User-supplied E = 10000 MPa; Ideal effective length factor = 1 ratio. Results retain the model limitations described above.
Common questions
Is Euler critical load a safe working load?
No. It is an idealized instability value, not a rated or code-adjusted capacity.
Does it verify the effective length factor?
No. End-restraint behavior must be independently justified.
Can it replace a wood post or stud design check?
No. Actual wood-column design involves additional material and stability checks.
How do I use this wood column euler model calculator?
Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E. Euler critical load = π² E Iweak / (K L)²; Iweak is the smaller rectangular principal second moment. Read the dimensioned examples below before entering project values.
Do starting values represent product or code recommendations?
No. They are stated calculation examples. Verify actual dimensions, material or product properties, units and site conditions. Neither a positive result nor an example value establishes a certified product, allowed load, compliant layout or current market price.
Can I export the result to Excel?
After calculating, use Export CSV. Excel can open the numeric results and submitted inputs. This is a text export, not a native formula workbook, desktop app or downloadable design package.
Where do the formulas and data come from?
Method and material references are listed below as plain-text addresses. Dimensional tables are calculated here from the stated inputs. Product density examples retain their species, moisture or manufacturer basis. Sources are not fetched when you use the calculator.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- USDA Wood Handbook 2021, Chapter 9: Table 9-1, equations 9-3, 9-4, 9-13, 9-14 and 9-25https://research.fs.usda.gov/download/treesearch/62251.pdf
- NIST SP 811, Appendix B.9: mass, length, area and volume conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9