Wood CalculatorMeasure, plan & work with wood

Wood calculators / Bounded elastic models

Measure the wood. State the basis.

Wood Column Euler Model Calculator

Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E.

Your wood & project inputs

mm
mm
m
MPa
ratio

Starting values are calculation examples. Verify actual dimensions, moisture basis, rates and model assumptions. Dimension-unit switching does not change fixed-unit price or engineering-property inputs.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Euler critical load = π² E Iweak / (K L)²; Iweak is the smaller rectangular principal second moment.

Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E.

  1. Confirm the physical, product or tally basis and use the stated units.
  2. Enter actual measurements and justified properties, prices or project allowances.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not an allowable wood-column, post or stud capacity. Crushing, imperfections, eccentricity, end restraint verification, NDS column factors, connections and load combinations are excluded.

Wood Column Euler Model: formula, units and interpretation

Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E. Not an allowable wood-column, post or stud capacity. Crushing, imperfections, eccentricity, end restraint verification, NDS column factors, connections and load combinations are excluded.

Separate the measured physical quantity from the purchase or design convention. Nominal lumber names, finished dimensions, geometric board feet, log-rule yield, stacked cords and mass describe different things. The method on this page uses only the basis stated beside its inputs; do not replace a missing property with an unrelated unit or trade name.

Before using the answer for a real project, confirm measurements and the relevant supplier information. Entered waste, prices, material properties and limits remain user choices. A rounded purchasing count is a quantity allowance rather than a cutting plan, and a calculated physical response is not a building-code approval.

Check the numbers

Wood Column Euler Model Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not stock recommendations, current quotes, code design values or full standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Rectangular first side = 100 mm; Rectangular second side = 150 mm; Unbraced ideal member length = 3 m; User-supplied E = 10000 MPa; Ideal effective length factor = 1 ratio.

OutputComputed result
Ideal elastic Euler critical load137.077839 kN critical
Weak-axis second moment1.25e-5 m⁴
Effective length3 m

How the stated input changes the result

ScenarioChanged input / basisResult
1.5 mUnbraced ideal member length548.311356 kN critical
2.25 mUnbraced ideal member length243.693936 kN critical
3 mUnbraced ideal member length137.077839 kN critical
3.75 mUnbraced ideal member length87.729817 kN critical
4.5 mUnbraced ideal member length60.923484 kN critical
6 mUnbraced ideal member length34.26946 kN critical

Unchanged inputs use: Dimension units = Metric (m / mm); Rectangular first side = 100 mm; Rectangular second side = 150 mm; Unbraced ideal member length = 3 m; User-supplied E = 10000 MPa; Ideal effective length factor = 1 ratio. Results retain the model limitations described above.

Common questions

Is Euler critical load a safe working load?

No. It is an idealized instability value, not a rated or code-adjusted capacity.

Does it verify the effective length factor?

No. End-restraint behavior must be independently justified.

Can it replace a wood post or stud design check?

No. Actual wood-column design involves additional material and stability checks.

How do I use this wood column euler model calculator?

Calculate an ideal elastic weak-axis buckling critical load from supplied dimensions and E. Euler critical load = π² E Iweak / (K L)²; Iweak is the smaller rectangular principal second moment. Read the dimensioned examples below before entering project values.

Do starting values represent product or code recommendations?

No. They are stated calculation examples. Verify actual dimensions, material or product properties, units and site conditions. Neither a positive result nor an example value establishes a certified product, allowed load, compliant layout or current market price.

Can I export the result to Excel?

After calculating, use Export CSV. Excel can open the numeric results and submitted inputs. This is a text export, not a native formula workbook, desktop app or downloadable design package.

Where do the formulas and data come from?

Method and material references are listed below as plain-text addresses. Dimensional tables are calculated here from the stated inputs. Product density examples retain their species, moisture or manufacturer basis. Sources are not fetched when you use the calculator.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • USDA Wood Handbook 2021, Chapter 9: Table 9-1, equations 9-3, 9-4, 9-13, 9-14 and 9-25https://research.fs.usda.gov/download/treesearch/62251.pdf
  • NIST SP 811, Appendix B.9: mass, length, area and volume conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9